Instaleaza gratuit aplicatia pentru Android
ELECTRONICE
  • Toata tara
    CAUTA

    DETECTOR PENTRU SISTEME DE INTERCEPTIE ( MICROFOANE )


    350 EUR
    MesajFavorite
    Alerta pret


    Adaugat la data de 4 Oct 2008 21:10 - ID: 9612  

    DESCRIERE
    Introduction
      
      The Aceco SC-1 hand-held radio frequency counter and detector is compact, truly pocket-sized, versatile test instrument designed for scan and detecting micro transmitters also any analog digital, on/off keying signal on frequencies between 30 MHz and 2.8 GHz. Supplied as a complete with internal NiCd pack, AC wall charger and 7 section telescopic antenna.
      
      
      Specifications
      
      Impedance: 50 Ohms (BNC Socket) VSWR less than 2:1
      Frequency range: 30 MHz – 2.8 GHz
      Sensitivity: less than 5 mV
      Max. input: 15 dBm
      Resolution: 10 KHz for digital Signals or On/Off Keying
      1 KHz for Analog Signals
      Timebase: Less than 1 PPM at room temperature
      Weight: 210 g
      Size: 80 mm high x 68 mm wide x 31 mm deep
      Case: Stamped aluminum with black anodized finish
      Battery: Internal 4 x AA 600 mAH NiCd pack
      Power: 9 VDC 300 mA
      
      
      Features
      
       7 digit Liquid Crystal Display
       Frequency counter for digital, on/off keying and analog signals with a minimum pulse width of 250 uS.
       Ultra sensitive synchronous detector - 16 section bargraph to show RF signal strength (-35dBm to 0 dBm)
       Two range positions - the 1 GHz position for frequencies between 30 MHz and 1 GHz and the 2.8 GHz position for frequencies between 500 MHz and 2.8 GHz.
       Squelch adjustment for input signals
       Hold switch to lock display
       Low battery indicator
       Low power consumption (Average 5 hour battery life)
       Supplied with NiCd pack, AC wall charger and telescopic antenna (143 MHz to 460 MHz)
      
      
      Controls
      
      1. SQL Knob - This knob turns the RF counter on and tunes the squelch up or down to set the signal strength for reception.
      2. Range Switch - This should be switched to the 1 GHz position for frequencies between 30 MHz and 0.8 GHz and switched to the 2.8 GHz position for frequencies between 500 MHz and 2.8 GHz.
      3. Hold Button - This holds the current display and stops the counter from counting.
      4. Calibration - The calibration adjustment opening is located on the front panel of the counter. This allows access to the trimmer capacitor that provides about a 10 PPM adjustment range of the time base oscillator. This is not usually necessary but to do so read a signal of a known frequency before adjusting the trimmer for correct frequency display. If you calibrate at 4.1943 MHz or above then the counter will be more accurate.


    IMAGINI


    MESAJ


    COMENTARII SI RECENZII
    4 Oct 2008  ·  Valabilit. 4 Oct 2009  ·  Afisari : 32  ·  Modificati anuntul  · Semnalati o neregula     




    BADER GHEORGHE


    Home · Adauga anunt · Modifica anunt · Login · Inregistrare firma · Forum · Widget anunturi · Semnalati o neregula · Contactati echipa Anunturi AZ ·

    Index produse:   A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   X   Y   Z
    Descarca gratuit aplicatia pentru telefonul tau


    Va doriti propriile produse listate aici ? Creati-va propriul magazin virtual pe aaz.ro.

    Informatiile despre preturi, produse si servicii sunt oferite de terte parti si doar pentru informare. AAZ.ro nu garanteaza acuratetea informatiilor si nu este raspunzator pentru nici o eroare, omisiune sau intarzieri,
    nici pentru orice neintelegeri sau pierderi datorita acestor informatii. Termeni si conditii | Politica de confidentialitate | Stergerea contului | Cookies | Siguranta online | ANPC | Contact



    Verified by VISA MasterCard SecureCode
    AAZ.ro © 2008